0 EA
no
show
  
Àαâ°Ë»ö¾î > °èÃø±â  ÃøÁ¤±â  ½ÃÇè±âÅ×½ºÅÍ±â  °Ë»ç±â  ŽÁö±â 
»óÇ°¼ö : 0 °³ + ¹è¼Û·á : 0 ¿ø = ÇÕ°è : 0 ¿ø
   ÇöÀçÀ§Ä¡ : HOME > Àü±â ÀüÀÚ °èÃø±â  >  ÇÔ¼ö/ÆÞ½º/ÆÐÅÏ/Æò¼±/ÀÓÀÇÆÄÇà/½ÅÈ£¹ß»ý±â  >  
½ÅÈ£¹ß»ý±â ,HANDY CALIBRATOR ,½ÅÈ£¹ß»ý±â , CA150
ÆǸŰ¡°Ý  : 3,872,000¿ø [VATÆ÷ÇÔ]
ºê·£µå  : yokogawa
Á¦Á¶»ç  : Japan
Á¦Ç°Äڵ堠: CA150
¹«ÀÌÀÚÇҺΠ :
¼Ò°³Çϱ⠠:
ÁÖ¹®¼ö·®  :
°³
 Á¦Ç°°ü·Ã ÀÚ·á PDF

Multi-functional Hand-held Calibrator
Highly accurate within 0.02% of the DC voltage range for source and measure
Source and measurement can be performed simultaneously.
Vertical body with large-screen display
Loop power supply function (24 VDC at a load of max 22 mA)
It is possible to measure current in the mA range while supplying power.
Sink function
Sweep functions that allow 3 types of continuous outputs:
Step sweep function
Linear sweep function
Program sweep function 

 

Specifications - Model CA150

Standard Accessories None
Power Supply 6 AA size alkaline batteries
AC adapter (sold separately)
AC adapter specification: 100 to 240 VAC, 50/60 Hz, 1.4 A
Dedicated NiMH battery (sold separately)
OUTPUT: 12 VDC, 3 A
Auto power-off Approx. 10 minutes; it can be canceled by setting.
Operating Temperature/Humidity Range 0 to 40¡ÆC, 20 to 80 % RH (no condensation)
Storage Temperature Range -20 to 60¡ÆC 90%RH or less (no condensation)
External Dimensions 251 x 124 x 70 mm
Weight Approx. 1000 g
Conforming Standards Safety Softy EN61010-1
EMC EN 61326 Class B;EN 55011 Class B Group1
EN 61000-3-2; EN 61000-3-3, EN61326

Product Overview

Vertical Hand-Held Calibrator Easy-to-hold vertical body is designed to make it intuitively easy to operate, as individual functions are accessed directly by pressing assigned keys.
Using the main body case (model No. 93027) (sold separately), you can hang CA150 to your body or a handrail to keep it handy.
Simultaneous Source and Measurement for Process Devices In conventional calibration applications, multiple devices such as a standard generator, dial resistor and multi-meter were required. Now with a single CA150 unit, it is possible to perform operation check at regular inspection and maintenance of thermocouples, RTDs and instruments, as well as maintenance and equipment diagnosis of process devices such as transmitters, thermostats and signal converters.
Loop Power Supply Function It is possible to measure generated current signals while supplying loop power 24 VDC from a two-wire type transmitter (up to 22 mADC).
Highly Accurate and Multi-Functional Source and Measurement High accuracy: 0.02% for the source unit and 0.02% for the measurement unit
Source and Measurement functions: DCV voltage, DC mA, ohm, frequency and temperature (thermocouple, RTD) and 24 VDC power supply function for transmitters
Output Functions Automatic Output Functions
  • Step sweep function
    This function changes the output in a staircase (step) pattern at fixed intervals.
  • Linear sweep function
    This function increases (or decreases) the output linearly with respect to the generated value.
  • Program sweep function
    This function outputs source setting values stored by the data memory function sequentially in the order they are stored in the memory.
Communication Functions Serial interface RS232 D-Sub 9-pin connector
Memory Function Data can be stored and loaded in setting memory (setting data) and data memory (source/measurement).
  • Setting memory
    This function saves/loads setting conditions.
    Up to 21 data items can be stored. Settings for (source/measurement) functions, ranges, generated values/measured values as well as setting mode conditions can be stored.
  • Data memory
    This function saves source and measure values displayed.
    Up to 100 data items can be stored. Storage date/time, (source/measurement) functions, ranges and generated values/measured values can be stored. Stored data can be checked on the display of the main unit as well as via communication.

 

 

À̸§ ¼³¸í ÆÄÀÏ À¯Çü  
CA150 Apps Notes   pdf icon
1.68 MB
´Ù¿î·Îµå
CA150 Apps Notes Spanish   pdf icon
1.43 MB
´Ù¿î·Îµå
External Dim   jpg icon
61 KB
´Ù¿î·Îµå
CA150 Bulletin   pdf icon
517 KB
´Ù¿î·Îµå

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í ½ÅÈ£¹ß»ý±â ,HANDY CALIBRATOR ,½ÅÈ£¹ß»ý±â , CA150
ÆǸŰ¡°Ý 3,872,000¿ø
ºê·£µå yokogawa
Á¦Á¶»ç Japan
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
ȸ»ç : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷| ´ëÇ¥ÀüÈ­ : 032-555-5645| Æѽº : 032-571-4445| glovebox-kr@naver.com
ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ 32 1Ãþ (ÀÛÀüµ¿)| »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 [»ç¾÷ÀÚ¹øÈ£Á¶È¸]
´ëÇ¥ : ÇãÁ¾¼ø| Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£

COPYRIGHT (C) HY »ê¾÷ ALL RIGHT RESERVED.