Water bath control temperature range from ambient +5¡É to 99.9¡É,

with large volume of internal and external circulation pump

Internal circulation pump enables precise temperature uniformity in the bath within ¡¾ 0.3¡É comparing to conventional heated water bath without circulation system.

 

External circulation pump enables to circulates water (liquid) to

external equipments which needs to be kept constant temperature.

External circulation flow rate is 7 ~ 20 liters/minute and pressure is 450 mbar.

Main Specifications


¢ºTemp. Range  : ambient +5
¡É ~ 99¡É             

¢ºController     : Digital PID Control

¢ºAccuracy     : ¡¾ 0.1¡É

¢ºUniformity    : ¡¾ 0.3¡É

¢ºCirculation    : Internal and external up to 7 ~ 20 liters/min

¢ºCapacity     : 50 / 100 Liters

 

Á¤¹Ð¿ÂµµÁ¦¾î


½ºÅ×Àη¹½º È÷ÅÍ¿Í ¸¶±×³×Æ® ÆßÇÁ·Î ¼øȯµÇ¾î ¿Âµµ°¡ Á¤¹ÐÇÏ°í ³»ºÎ ¶Ç´Â ¿Ü¹«±â±â¿¡ Ç׿¼ö¸¦ °ø±Þ

ÃÖ´ë 99¡É, ¡¾ 0.1¡É Á¤¹Ðµµ¿Í ¡¾ 0.3¡ÉÀÇ ¿Âµµ ºÐÆ÷

µðÁöÅÐ PID Á¦¾î ¹æ½ÄÀ¸·Î ¡¾ 0.1¡ÉÀ̳»ÀÇ ¿Âµµ Á¦¾î

°ú¿­ ¹æÁö ÀåÄ¡, ¾Ë¶÷, ŸÀ̸Ó, ¿ÀÅäÆ©´×, ¿Âµµ º¸Á¤ ±â´É


 

Æí¸®ÇÑ ¼øȯ±â´É


½ºÅ×Àη¹½º ÀçÁúÀÇ ¹è½º´Â ºÎ½Ä¿¡ °­ÇÏ°í ABS ÀçÁúÀÇ ÆßÇÁ ¾î¼Àºí¸®´Â ºÎ½Ä¿¡ °­ÇÔ. ¸¶±×³×ƽ ÆßÇÁ´Â 7¶Ç´Â 20L/ºÐ, 450mbarÀÇ ³ôÀº ¾Ð·ÂÀ¸·Î ¼öÁ¶ ³»ºÎ¿Í ¿ÜºÎ·Î Ç׿¼ö¸¦ ¼øȯ



Specifications & Ordering Information


Cat.No Descript-xion Size
JSIB-50T Internal and External up to 7~20 liters/min 50L
JSIB-100T Internal and External up to 7~20 liters/min 100L
JSIB-30T Internal and External up to 7~20 liters/min 30L



Model
JSIB-30T
JSIB-50T
JSIB-100T
Bath Capacity(Volume)
30L
50L
100L
Dimensions W*D*H mm
Inner
300*490*200
300*400*400
400*500*500
Outer
380*760*430
400*550*550
500*650*650
Usable
300*490*150
300*440*350
400*500*450
Tempperature
Range
ambient +5¡É ~ 99¡É
Accuracy
¡¾0.1 ¡É
Uniformity
¡¾0.3 ¡É
Material
Bath
Stainless Steel 304
Body
Steel with Epoxy Powder Coating
Circulation Pump
Internal and External / Capacity 7L/min.for30T&50T,20L/min for100T / 450mbar
Controller
Digital PID controller with Timer and Auto-Tuning
Display
4 Digit LED Dispaly
Sensor
Pt 100 §Ù
Safety
Over Temp. Cut-Out / Over Current Leakage Breaker
Electrical Requirement
220 VAC 50/60 Hz or 120 VAC60 Hz

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í Ç׿ ¼öÁ¶(30L)
ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
ºê·£µå JSR
Á¦Á¶»ç korea
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
ȸ»ç : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷| ´ëÇ¥ÀüÈ­ : 032-555-5645| Æѽº : 032-571-4445| glovebox-kr@naver.com
ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ 32 1Ãþ (ÀÛÀüµ¿)| »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 [»ç¾÷ÀÚ¹øÈ£Á¶È¸]
´ëÇ¥ : ÇãÁ¾¼ø| Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£

COPYRIGHT (C) HY »ê¾÷ ALL RIGHT RESERVED.