0 EA
no
show
  
Àαâ°Ë»ö¾î > °èÃø±â  ÃøÁ¤±â  ½ÃÇè±âÅ×½ºÅÍ±â  °Ë»ç±â  ŽÁö±â 
»óÇ°¼ö : 0 °³ + ¹è¼Û·á : 0 ¿ø = ÇÕ°è : 0 ¿ø
   ÇöÀçÀ§Ä¡ : HOME > ÀÌÈ­ÇÐ/°úÇбâ/±¼Àý/Æí±¤ /ÈÖµµ /½ÇÇèÃÊÀÚ/¼¼¶ó¹Í  >  
**ÇÙ»êÁ¤Á¦ Automated Electrophoresis - QIAxcel Advanced System ÀÚµ¿Àü±â¿µµ¿
ÆǸŰ¡°Ý  : 62,150,000¿ø [VATÆ÷ÇÔ]
ºê·£µå  : QIAGEN
Á¦Á¶»ç  : USA
¹«ÀÌÀÚÇҺΠ :
¼Ò°³Çϱ⠠:
ÁÖ¹®¼ö·®  :
°³

 
ÇÙ»êÁ¤Á¦
QXA.gif

´Ù¼Ò °í³­µµÀÇ ÀÛ¾÷ ¼÷·Ãµµ°¡ ÇÊ¿äÇÏ°í º¹ÀâÇÑ ÀÛ¾÷°úÀåÀÌ ¿ä±¸µÇ¹Ç·Î ÀÚµ¿È­ÇÏ¿© Human error¸¦ ÃÖ¼ÒÈ­ÇÏ°í Ç¥ÁØÈ­ÇÒ ÇÊ¿ä°¡ ³ôÀº °úÁ¤ÀÔ´Ï´Ù. ½Ã·áÀÇ ¼ö·®¿¡ µû¶ó ȤÀº ¿ëµµ¿¡ µû¶ó ÁغñµÈ ÀüÀÚµ¿ ÇÙ»êÃßÃâÀåÄ¡

 

ÇÙ»êÁ¤Á¦
 
EZ1 Advanced XL
14°³ ½Ã·á¸¦ 20ºÐ¸¸¿¡! ÃÊ°í¼Ó ÃÊ°£´Ü ÇÙ»êÃßÃâÀåÄ¡
QIAcube
QIAGEN spin kit¸¦ ±×´ë·Î ÀÚµ¿È­
QIAsymphony
½Ã·áÀÇ ¾ç°ú ¼ö ±×¸®°í application Á¦¾àÀÌ ¾ø´Â ÇÙ»êÃßÃâÀåÄ¡
QIAxtractor
°¡Àå ÀÛ°í °æÁ¦ÀûÀÎ 96well Çü½Ä ÇÙ»êÃßÃâÀåÄ¡
BioRobot MDX
ȯÀڽ÷ῡ¼­ ÇÙ»êÀ» ÃßÃâÇÏ´Â ´ë·®/°í¼Ó ÇÙ»êÃßÃâÀåÄ¡
Autopure LS
Blood banking¿ë large volume ÇÙ»êÃßÃâÀåÄ¡

 

EZ1 Advanced XL

 
 
EZ1 Advanced XL
 
- High-quality genomic DNA and RNA from a range of sample materials
- Viral nucleic acids from serum, plasma, CSF, urine, and respiratory samples
- Throughput of up to 6 or up to 14 samples per run
- Effortless data management with full traceability
- UV lamp helps to prevent cross-contamination

QIAsymphony

 
 
QIAsymphony
 
- »ç¿ëÇϱ⠽¬¿î, »õ·Î¿î ÇüÅÂÀÇ ¹Ì¸® ¿ë¾×À» ä¿îreagent cartridgeÇüÅÂ
- run´ç 1¿¡¼­96°³ »ùÇñîÁö ¿øÇÏ´Â ¸¸Å­ 󸮰¡´É
- Large sample volumesÀ¸·Î high yields¿Í sensitivity ȹµæ
- Çõ½ÅÀûÀÎ DesignÀ» ÅëÇÑ ¾ÈÀüÇÏ°í Áøº¸µÈ ½ÇÇè°úÁ¤À» Á¦°øÇÔ
- °¡Àå ÃÖ½ÅÀÇ service¿Í support¸¦ À§ÇÑ QIAGEN Device Management

BioRobot

 
 
BioRobot
 
- cells, tissues, ±×¸®°í blood¿¡¼­ RNA Á¤Á¦
- swabs°ú blood¿¡¼­ genomic DNAÁ¤¿¡, media¿¡¼­ bacterial DNAÁ¤Á¦ ±×¸¯°í E. coli¿¡¼­ plasmid Á¤Á¦
- sputum, plasma, and respiratory samples¿¡¼­ virus ÇÙ»ê Á¤Á¦
- forensic casework samples¿¡¼­ genomic DNA Á¤Á¦
- Comprehensive support with service coverage tailored to your needs

QIAcube

 
 
QIAcube
 
- ¸ðµç QIAGEN spin-columnÀ» ÀÌ¿ëÇÑ Prep¿¡ Àû¿ë°¡´ÉÇÑ ÀüÀÚµ¿ Àåºñ
- ¸Å´º¾ó·Î ÇÏ´Â ¹ø°Å·Î¿î ÀϷκÎÅÍ ¹þ¾î³²
- run´ç ÃÖ´ë 12 sample ±îÁö DNA, RNA, ¶Ç´Â proteins Á¤Á¦
- Unparalleled ease of use
- ¾÷¹«´É·Â Çâ»ó°ú ÀÛ¾÷°øÁ¤ Ç¥ÁØÈ­

QIAxtractor

 
 
QIAxtractor
 
- µ¿½Ã¿¡ 8-96 »ùÇà ó¸®, 96ºÐ ¾È¿¡ 96°³ÀÇ »ùÇà ó¸®
- ÃÖÀûÈ­µÈ Àü¿ë kit¿Í protocol·Î ¾çÁúÀÇ ÇÙ»ê Á¤Á¦
- 32kgÀÇ ¸Å¿ì ÀÛÀº »çÀÌÁî·Î ¼³Ä¡¿Í À̵¿ÀÌ ¿ëÀÌÇÔ
- Á÷°üÀûÀÌ°í ¹è¿ì±â ½¬¿î ¼ÒÇÁÆ®¿þ¾î·Î ´©±¸³ª »ç¿ëÀÌ °¡´É
- UV ¸ê±Õ ÀåÄ¡ ¹× HEPA ÇÊÅÍ Ã¤¿ëÀ¸·Î ¾ÈÀüÇÑ ÀÛ¾÷ȯ°æ

Autopure LS

 
 
Autopure LS
 
- Walkaway purification of DNA suitable for archiving
- 10mlÀÇ blood´ç 500ugÀÇ DNA ÃßÃâ °¡´É.
- ´Ù¾çÇÑ »ùÇÃÁ¾·ù¿Í ¾çÀ¸·Î ºÎÅÍ DNAºÐ¸®Á¤Á¦°¡ °¡´ÉÇÔ
- Archiving¿¡ Àû´çÇÑ ¸Å¿ì ¾ÈÁ¤ÇÑ DNA Á¤Á¦

https://www.qiagen.com/kr/shop/automated-solutions/accessories/qiaxcel-rna-accessories/#orderinginformation

 

https://www.qiagen.com/kr/shop/automated-solutions/accessories/qiaxcel-dna-accessories/#orderinginformation

 

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í **ÇÙ»êÁ¤Á¦ Automated Electrophoresis - QIAxcel Advanced System ÀÚµ¿Àü±â¿µµ¿
ÆǸŰ¡°Ý 62,150,000¿ø
ºê·£µå QIAGEN
Á¦Á¶»ç USA
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
ȸ»ç : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷| ´ëÇ¥ÀüÈ­ : 032-555-5645| Æѽº : 032-571-4445| glovebox-kr@naver.com
ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ 32 1Ãþ (ÀÛÀüµ¿)| »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 [»ç¾÷ÀÚ¹øÈ£Á¶È¸]
´ëÇ¥ : ÇãÁ¾¼ø| Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£

COPYRIGHT (C) HY »ê¾÷ ALL RIGHT RESERVED.