»ïÅõ¾Ð ÃøÁ¤±â ,µ¶ÀÏ, Osmomat 3000 ,Osmomat 3000D (ÇÁ¸°Åͳ»ÀåÇü)
ÆǸŰ¡°Ý : |
11,220,000¿ø [VATÆ÷ÇÔ]
|
¿ø»êÁö : |
Germany |
ºê·£µå : |
Gonotec |
Á¦Á¶»ç : |
Gonotec |
Á¦Ç°ÄÚµå : |
Osmomat 030 |
* ±Ô°Ý¼±Åà : |
|
¹«ÀÌÀÚÇҺΠ: |
|
ºñ¾¾ 2,3°³¿ù (5¸¸¿ø¡è) |
|
LG 2,3°³¿ù (5¸¸¿ø¡è) |
|
±¹¹Î 2,3°³¿ù (5¸¸¿ø¡è) |
|
½ÅÇÑ 2,3°³¿ù (5¸¸¿ø¡è) |
|
Çö´ë 2,3°³¿ù (5¸¸¿ø¡è) |
|
·Ôµ¥ 2,3°³¿ù (5¸¸¿ø¡è) |
|
»ï¼º 2,3°³¿ù (5¸¸¿ø¡è) |
|
¿Üȯ 2,3°³¿ù (5¸¸¿ø¡è) |
|
ÇϳªSK 2,3°³¿ù (5¸¸¿ø¡è) |
|
|
¼Ò°³Çϱâ : |
|
|
0¿ø X
|
|
0¿ø
|
|
»óÇ°ÃÑ ±Ý¾× :
ÇÒÀÎ±Ý¾× :
|
Á¦Ç°°ü·Ã ÀÚ·á PDF
* »ïÅõ¾ÐÃøÁ¤±âOsmomat 3000 /GONOTEC/µ¶ÀÏ
1.Ư¡
*. ¼ö¿ë¼º »ùÇÃÀÇ ½Å¼ÓÇÑ »ïÅõ¾Ð ÃøÁ¤ (1 sample)
* ÅÍÄ¡ ½ºÅ©¸°À¸·Î Æí¸®ÇÑ »ç¿ë
* °ß°íÇÑ µðÀÚÀÎ
*. 2 ¶Ç´Â 3 point calibration °¡´É
* USB, RS232·Î µ¥ÀÌÅÍ Àü¼Û °¡´É
* Á¤È®ÇÏ°í È¿À²ÀûÀÎ ½Ã½ºÅÛ
2.±Ô°Ý
1) ½Ã·á¿ë·® : 50§¡
2) ÃøÁ¤½Ã°£ : ¾à 1ºÐ
3) ÀçÇö¼º : ¡Â¡¾2 digit [0...400] mOsmol/kg H©üO
¡Â¡¾0.5% digit [400...1500] mOsmol/kg H©üO
¡Â¡¾1.0% digit [1500..3000] mOsmol/kg H©üO
4) µð½ºÇ÷¹ÀÌ : 5.7" LCD - ÅÍÄ¡½ºÅ©¸°
5) ÃøÁ¤ ¹üÀ§ : ¾à 3000 mOsmol /kg
6) Àд °ª(´ÜÀ§) : 1 mOsmol/kg
7) ÃøÁ¤¹æ¹ý : ¾óÀ½ÀÇ Å©¸®½ºÅ»È°¡ µÇ¸é, sus ´Ïµé·Î
Å©¸®½ºÅ» Ç¥¸éÀ» ¼ø°£ÀûÀ¸·Î ±ü´Ù.
8) ³Ã°¢ : ÆçƼ¾î ¹ÝµµÃ¼ Ĩ
9) ³Ã°¢ Á¤µµ : <¡¾0.1¡É
10) ½ÇÇè¿Âµµ : 10¡É ¢¦ 35¡É
11) ¿¬°áÆ÷Æ® : DTE RS-232, USB
12) Àü¿ø : 220v, 50/60Hz
13) ±Ô°Ý : 220 x 205 x 360mm
14) Áß·® : ¾à 6.4kg
±âº»¾Ç¼¼»ç¸®
1. ÃøÁ¤ º£¼¿ 100ea
2. (300mOsmol) Calibration Solution(1ml) 10ea
Á¦Ç°°ü·Ã ÀÚ·á PDF
Ư¡ ¹× ¼Ò°³ ³»¿ë¢Ñ »ùÇà ¼Ö·ç¼Ç ÆçƼ¾î ³Ã°¢ syste¿¡ ÀÇÇØ ³Ã°¢µÇ¾î ¿Âµµ´Â ÀüÀÚ Á¦¾îµÇ°í. »ùÇà olutionÀÌ ¾î´ÂÁ¡ ¾Æ·¡ÀÇ ¸ñÇ¥ ¿Âµµ¿¡ µµ´ÞÇÏ¸é ½Ã·áÀÇ °áÁ¤È °úÁ¤ÀÌ ÀÚµ¿À¸·Î ½ÃÀ۵˴ϴÙ. ÀÌ ¹Ù´ÃÀº ÈÄÀÚ¿¡ ¶Ù¾îµé °ÍÀԴϴ٠ªÀº ÇØ»óµµ ÃøÁ¤,ÀÌ (½ºÅ×Àη¹½º ½ºÆ¿ ¹Ù´ÃÀº ÀÛÀº ¾óÀ½ °áÁ¤ÀÌÀÇ ÆÁ¿¡ Ãæ½Ç ±×·¯ÇÑ ¹üÀ§ ³»¿¡¼ µÎ ¹ø° ³Ã°¢ ½Ã½ºÅÛ¿¡ ÀÇÇØ ³Ã°¢ ¼Ö·ç¼Ç¿¡ ¾óÀ½ °áÁ¤ injecing ÅëÇØ ÀÌ·ç¾îÁý´Ï´Ù ½Ã°£). ÀÌÇÏ ¿Âµµ°¡ »ó½Â Àº °á°úÀÇ ÀçÇö¼ºÀº Ç¥ÁØ supercooling ¿Âµµ¿¡¼ °áÁ¤È °úÁ¤ÀÇ Á¤È®ÇÑ °³½Ã¿¡ È®½ÇÈ÷ µû¶ó (À§¿¡ ±×¸² ÂüÁ¶). 1.858/1000ÀÇ °áÁ¤ ¡É¿¡ µµ´Þ ÀÚ¹ßÀû untal. |
Ư¡ ¹× ¼Ò°³³»¿ë¢Ñ The sample solution is cooled by means of a peltier cooling syste, the temperature being electronically controlled. When the sample olution has reached its target temperature below the freezing point, the crystallization process of the sample is automatically initiated. This is done by injecing ice crystals into the solution (a stainless steel needle is cooled by means of a second cooling system to such an extent that tiny ice crystals stick to its tip; this needle is plunged into the latter is measured with a resolution short time). Hereafter the temperature rises spontaneously untal it has reached the crystallization of 1.858/1000¡É (see diagram on the above.) The reproducibility of the result depends definitely on the exact initiation of the crystallization process at the standardized supercooling temperature. |
* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í |
»ïÅõ¾Ð ÃøÁ¤±â ,µ¶ÀÏ, Osmomat 3000 ,Osmomat 3000D (ÇÁ¸°Åͳ»ÀåÇü) |
ÆǸŰ¡°Ý |
11,220,000¿ø |
ºê·£µå |
Gonotec |
¿ø»êÁö |
Germany |
Á¦Á¶»ç |
Gonotec |
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
Åùè¹ß¼Û èâ ¿ë´Þ,Äü,ȹ°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.