0 EA
no
show
  
Àαâ°Ë»ö¾î > °èÃø±â  ÃøÁ¤±â  ½ÃÇè±âÅ×½ºÅÍ±â  °Ë»ç±â  ŽÁö±â 
»óÇ°¼ö : 0 °³ + ¹è¼Û·á : 0 ¿ø = ÇÕ°è : 0 ¿ø
   ÇöÀçÀ§Ä¡ : HOME > ºÐ¼®±â- ¼öÁú/°¡½º/ÀÔµµ/Áøµ¿/¹æ»ç´É/±â»ó°üÃø/¿Â½Àµµ ÃøÁ¤±â   >  ¼öÁú ÃøÁ¤±â  >  
HACH ½ÇÇè½Ç¿ë ÀüµµµµÃøÁ¤±â, HQ1140-CDC40101
Àüµµµµ: 0.01µS/cm ~ 200mS/cm
ÆǸŰ¡°Ý  : 2,160,000¿ø [VATÆ÷ÇÔ]
ºê·£µå  : HACH
Á¦Ç°Äڵ堠: HQ1140-CDC40101
¹«ÀÌÀÚÇҺΠ :
¼Ò°³Çϱ⠠:
ÁÖ¹®¼ö·®  :
°³

2.png

 





 


¡¤ Á¦ Ç° Ư ¡

¡¤ ¸ð  µ¨  ¸í : HQ1140-CDC40101

¡¤ ½ÇÇè½Ç¿ë ÀüµµµµÃøÁ¤±â

¡¤ Á¦  Á¶  »ç : HACH

¡¤ Àüµµµµ ¹üÀ§: 0.01¥ìS/cm ~ 200mS/cm

¡¤ ÄÉÀ̺í±æÀÌ: 1m



¡¤ Á¦ Ç° ±â ´É

¡¤ ÇÑ ´ëÀÇ Àåºñ·Î EC(Àüµµµµ) ¹× TDS, Salinity(¿°ºÐµµ), ¿ÂµµÀÇ ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù. 

¡¤ °£´ÜÇÑ Á¶ÀÛ°ú Á¤È®ÇÑ °á°ú°ªÀ» ÇÑ ´«¿¡ È®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.

¡¤ IntelliCAL ¢â ½º¸¶Æ® ÇÁ·Îºê´Â ÇÁ·ÎºêÀÇ ¸ðµç ±³Á¤À» ÀúÀåÇÕ´Ï´Ù.

¡¤ HQ ½Ã½ºÅÛÀº ¿ÏÀüÇÑ GLP ÃßÀûÀ»À§ÇÑ µ¥ÀÌÅÍ ·Î±×¿¡ ÀÚµ¿À¸·Î ÀÏ·Ã ¹øÈ£, ÇöÀç ±³Á¤ µ¥ÀÌÅÍ, »ç¿ëÀÚ ID, »ùÇà ID, ½Ã°£ ¹× ³¯Â¥¸¦​​ ±â·ÏÇÕ´Ï´Ù.

¡¤ °¢ Àü±ØÀÇ ¼±Åÿ¡ µû¶ó ÇöÀå ¹× ½ÇÇè½Ç¿¡¼­ »ç¿ëÀÌ ¸ðµÎ ¿ëÀÌÇÕ´Ï´Ù.

¡¤ Àü¿ø: ¸®Æ¬À̿¹èÅ͸® 18650(³»ºÎ) / 100-240VDC 5V DC (¿ÜºÎ)

¡¤ ¹æ¼öµî±Þ: IP67 (¹èÅ͸®ÀåÂø½Ã)

¡¤ µ¥ÀÌÅÍ ÀúÀå: 5,000°³ ÀúÀå

¡¤ µðÁöÅÐ(Áö´ÉÇü) Àü±Ø¿¬°á: 1ä³Î

¡¤ µð½ºÇ÷¹ÀÌ: 536 x 336 Mono-TFT, ¹é¶óÀÌÆ® Áö¿ø

¡¤ ¾ð¾î: Çѱ¹¾î Æ÷ÇÔ 27°³ ¾ð¾î Á¦°ø

¡¤ Ãâ·Â: USB ÄÉÀÌºí ¿¬°á PC ¹× USB Àü¼Û

¡¤ ºÐÇØ´É: 0.1 / 0.01 / 0.001

¡¤ Å©±â: 63 mm x 97 mm x 220 mm

¡¤ ¹«°Ô: 519g


¡¤ Àû¿ëºÐ¾ß

¡¤ ¼öÁú½ÃÇè, Æó¼öó¸®Àå, ¿À¼öó¸®Àå, Á¤¼öó¸®Àå, ½ÇÇè½Ç, ¾ç¾îÀå, ÃÊÁß°í ÇöÀå½Ç½À µî



¡¤ º» ü »ç ¾ç

±¸ºÐ

HQ1110

HQ1130

HQ1140

Á¦Ç° ¹øÈ£

LEV015.53.1110A

LEV015.53.1130A

LEV015.53.1140A

ÃøÁ¤ Ç׸ñ

pH

ORP

¿Âµµ

DO (¿ëÁ¸»ê¼Ò)

BOD

¿Âµµ

EC (Àüµµµµ)

TDS

Salinity (¿°µµ, ¿°ºÐµµ)

¿Âµµ

Àü±Ø ¿¬°á

1°³

1°³

1°³

È­¸é

536x336 Mono-TFT

¹é¶óÀÌÆ® Áö¿ø

536x336 Mono-TFT

¹é¶óÀÌÆ® Áö¿ø

536x336 Mono-TFT

¹é¶óÀÌÆ® Áö¿ø

µ¥ÀÌÅÍ ÀúÀå

5,000°³

5,000°³

5,000°³

µ¥ÀÌÅÍ Àü¼Û

USB ÄÉÀÌºí ¿¬°á PC ¹× USB Àü¼Û

USB ÄÉÀÌºí ¿¬°á PC ¹× USB Àü¼Û

USB ÄÉÀÌºí ¿¬°á PC ¹× USB Àü¼Û

ÃøÁ¤ ¸ðµå

´ÜÀÏ, ¿¬¼Ó, Interval

´ÜÀÏ, ¿¬¼Ó, Interval

´ÜÀÏ, ¿¬¼Ó, Interval

Àü¿ø °ø±Þ

¸®Æ¬À̿¹èÅ͸® 18650 (³»ºÎ)

100-240VDC 5V DC (¿ÜºÎ)

¸®Æ¬À̿¹èÅ͸® 18650 (³»ºÎ)

100-240VDC 5V DC (¿ÜºÎ)

¸®Æ¬À̿¹èÅ͸® 18650(³»ºÎ)

100-240VDC 5V DC (¿ÜºÎ)

Å©±â (mm)

(H x W x D)

63 x 97 x 220

63 x 97 x 220

63 x 97 x 220

¹«°Ô (g)

519

519

519

¹æ¼öµî±Þ

IP67

(¹èÅ͸®ÀåÂø½Ã)

IP67

(¹èÅ͸®ÀåÂø½Ã)

IP67

(¹èÅ͸®ÀåÂø½Ã)

¾ð¾î

Çѱ¹¾î Æ÷ÇÔ 27°³ ¾ð¾î Á¦°ø

Çѱ¹¾î Æ÷ÇÔ 27°³ ¾ð¾î Á¦°ø

Çѱ¹¾î Æ÷ÇÔ 27°³ ¾ð¾î Á¦°ø




±¸¼ºÇ°

HQ1110 ÃøÁ¤±â

¸Å´º¾ó

¸®Æ¬¹èÅ͸®

USBÀü¿øÃæÀü±â

USBÄÉÀ̺í

¿¬°á²ö

Àü±Ø¿¬°áÇ÷¯±×

USBÆ÷Æ®Ç÷¯±×

µå¶óÀ̹ö

HQ1130 ÃøÁ¤±â

¸Å´º¾ó

¸®Æ¬¹èÅ͸®

USBÀü¿øÃæÀü±â

USBÄÉÀ̺í

¿¬°á²ö

Àü±Ø¿¬°áÇ÷¯±×

USBÆ÷Æ®Ç÷¯±×

µå¶óÀ̹ö

HQ1140 ÃøÁ¤±â

¸Å´º¾ó

¸®Æ¬¹èÅ͸®

USBÀü¿øÃæÀü±â

USBÄÉÀ̺í

¿¬°á²ö

Àü±Ø¿¬°áÇ÷¯±×

USBÆ÷Æ®Ç÷¯±×

µå¶óÀ̹ö

 

 ¡¤ È£È¯ °¡´ÉÇÑ Àü±Ø HACH Àü±Ø ÁÖ¿ä ¸ðµ¨

¡¤ CDC40101 (½ÇÇè½Ç¿ë, 1M) - EC(Àüµµµµ) ¹× TDS, Salinity(¿°ºÐµµ), ÀúÇ×(Resist), ¿Âµµ ÃøÁ¤ °¡´É

¡¤ CDC40105 (ÇöÀå¿ë, 5M) - EC(Àüµµµµ) ¹× TDS, Salinity(¿°ºÐµµ),ÀúÇ×(Resist), ¿Âµµ ÃøÁ¤ °¡´É


Specifications

 Conductivity

 Conductivity

Prod. No.

CDC40101

CDC40105

Special Feature

 

  

Probe Type

Laboratory

Rugged Outdoor



Range


Cond.: 0.01 µS/cm ~ 200 mS/cm

TDS: 0 ~ 50,000 mg/L as NaCl 

Salinity: 0 ~ 42 % ¶Ç´Â g/kg

Resist.: 2.5 §Ùcm ~ 49 M§Ùcm 


Cond.: 0.01 µS/cm ~ 200 mS/cm

TDS: 0 ~ 50,000 mg/L as NaCl 

Salinity: 0 ~ 42 % ¶Ç´Â g/kg

Resist.: 2.5 §Ùcm ~ 49 M§Ùcm



Accuracy


Cond: ¡¾0.5% of range

TDS: ¡¾0.5% ¡¾1 digit

Salinity: ¡¾0.1, ¡¾1 digit


EC: 0.01 ¥ìS/cm

(5 digits, maximum)

TDS: 0.001, 0.01,

0.1 mg/L Salinity: 0.01 ppt


Temperature Range

-10 ~ 110 ¡ÆC

-10 ~ 110 ¡ÆC

Dimensions (D x L)

0.55 in x 7.87 in

(14 mm x 200 mm)

1.77 in x 9.84 in

(45 mm x 250 mm)

Sensor Type

4-pole graphite,

k = 0.40 cm-1

4-pole graphite,

k = 0.40 cm-1

Material

Sensor Body:

Noryl

Sensor Body:

Noryl with Stainless Steel

 

¡¤ Technical Data

 

Model

HQ1110

pH/ORP/ 

1 Channel

HQ1130

DO/

1 Channel

HQ1140

EC/TDS/

1 Channel

HQ2100

Multi/

1 Channel

HQ2200

Multi/

2 Channels

HQ4100

Multi/ISE/

1 Channel

HQ4200

Multi/ISE/ 

2 Channels

HQ4300

Multi/ISE/ 

3 Channels

Data Memory

5000 data points

10,000 data points

100,000 data points

Display Type

536x336 Mono-TFT

536x336 Mono-TFT

640x480 Color TFT

Inputs

1

1

2

1

2

3

Weight (Meter only)

519 g

519 g

541 g

530 g

550 g

570 g

Warranty

EU: 2 years

US and other geographies: 1 year

EU: 2 years

US and other geographies: 1 year

3 years

Dimensions (H x W x D)

63 mm x 97 mm x 220 mm

Enclosure Rating

IP67 (with battery compartment installed)

Data Storage

Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.

Data Export

USB connection to PC or USB storage device (limited to the storage device capacity).

Software available

Claros

Display

Up to 3 parameters at a time, dependent on HQ model

Backlight

Yes

Lock Function

Continuous / Auto-stabilization (¡°press to read¡±) / At Interval

Languages

English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian

Certifications

CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS

GLP Features

Date; Time; Sample ID; Operator ID, Calibration

Power Supply

Rechargeable lithium-ion battery 18650 (internal)

Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)

*Subject to change without notice.


 ¡¤ Parameter Table

 

Model

HQ1110

pH/ORP/ 

1 Channel

HQ1130

DO/

1 Channel

HQ1140 

EC/TDS/

1 Channel

HQ2100

Multi/

1 Channel

HQ2200

Multi/

2 Channels

HQ4100

Multi/ISE/ 

1 Channel

HQ4200

Multi/ISE/ 

2 Channels

HQ4300

Multi/ISE/ 

3 Channels

 

Temperature

 

pH

 

 

 

mV

 

 

 

Conductivity

 

 

 

TDS

 

 

 

Salinity

 

 

 

Resistivity

 

 

 

 

Dissolved Oxygen (LDO)

 

 

 

BOD (with LDO)

 

 

 

ORP/Redox

 

 

 

Ammonia

 

 

 

 

 

 

Ammonium

 

 

 

 

 

 

Chloride

 

 

 

 

 

 

Fluoride

 

 

 

 

 

 

Nitrate

 

 

 

 

 

 

Sodium

 

 

 

 

 

 

*Subject to change without notice.



 ¡¤ HQ Series Portable Standard Sensor Kits  

LEV015.53.11101

HQ1110 Portable Dedicated pH/ORP/mV Meter with Gel pH Electrode, 1 m Cable

LEV015.53.22004

HQ2200 Portable Multi-Meter with pH and Dissolved Oxygen Electrodes, 1 m Cables

LEV015.53.11301

HQ1130 Portable Dedicated Dissolved Oxygen Meter with Dissolved Oxygen Electrode, 1 m Cable

LEV015.53.42001

HQ4200 Portable Multi-Meter with Gel pH and Conductivity Electrode, 1 m Cables

LEV015.53.42005

HQ4200 Portable Multi-Meter with Gel pH and Dissolved Oxygen Electrode, 1 m Cables

LEV015.53.43001

HQ4300 Portable Multi-Meter with Gel pH, Conductivity, and Dissolved Oxygen Electrode, 1 m Cable


¡¤ HQ Series Portable Rugged Sensor Kits 

LEV015.53.11103

HQ1110 Portable Dedicated pH/ORP/mV Meter with Gel pH Electrode, 5 m Rugged Cable

LEV015.53.11302

HQ1130 Portable Dedicated Dissolved Oxygen Meter with Dissolved Oxygen Electrode, 5 m Rugged Cable

LEV015.53.22006

HQ2200 Portable Multi-Meter with pH and Dissolved Oxygen Electrode, 5 m Rugged Cables

LEV015.53.42006

HQ4200 Portable Multi-Meter with Gel pH and Dissolved Oxygen Electrode, 5 m Rugged Cables

LEV015.53.42003

HQ4200 Portable Multi-Meter with Gel pH and Conductivity Electrode, 5 m Rugged Cables

Additional Standard and Rugged Sensor Kits are available. Please contact Hach for more information.



¡¤ Accessories and Consumables

LEZ015.99.A001A

Portable HQ Series Standard Field Case for Standard Probes

LEZ015.99.A002A

Portable HQ Series Field Case for Rugged Probes with Extended Cable Lengths

LEZ015.99.A003A

Kick Stand and Hand Strap for Portable HQ Series Meter

LEZ015.99.A004A

Protective Glove for Portable HQ Series Meter

LZE015.99.A005A

Wrist Strap and Dust Plugs for Portable HQ Series Meter

LEZ015.99.00001

Li-Ion Battery Replacement, HQ Series Meter

LEZ015.99.00002

USB Cable for Portable HQ Series Meter

LEZ015.99.00006

Replacement Power Supply for HQ Series Meter, US

LEZ015.99.00004

Replacement Power Supply for HQ Series Meter, EU

 

 

 

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í HACH ½ÇÇè½Ç¿ë ÀüµµµµÃøÁ¤±â, HQ1140-CDC40101
ÆǸŰ¡°Ý 2,160,000¿ø
ºê·£µå HACH
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
ȸ»ç : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷| ´ëÇ¥ÀüÈ­ : 032-555-5645| Æѽº : 032-571-4445| glovebox-kr@naver.com
ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ 32 1Ãþ (ÀÛÀüµ¿)| »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 [»ç¾÷ÀÚ¹øÈ£Á¶È¸]
´ëÇ¥ : ÇãÁ¾¼ø| Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£

COPYRIGHT (C) HY »ê¾÷ ALL RIGHT RESERVED.